Comfort. Low Dose. Ultra-Versatility. The complete premium model of high-end Digital RF system.
Boost your productivity, reduce patient dose & anxiety and improve radiographer workload. Meet all-new CUREVISTA Open. Your X-ray experience will begin to evolve.
Evolution in Comfort. Evolution in Low Dose. Evolution in Versatility.
2 WAY ARM / Longitudinal & Lateral Direction
For safety reasons, you don’t want to move the patient. The X-ray tube column moves freely in vertical, horizontal & diagonal direction. No patient movement required to adjust FOV. This is a risk-reducing solution for doctors and radiographers who want to focus on examinations and procedures.
SYMMETRIC DESIGN / 9.8cm Blank Space
For doctors, posture may affect the accuracy of the procedure. With the symmetric table structure and a large scanning area, blank space (Non-radio-transparent area) is only 9.8 cm at both edges of the table. This is a result of considering the patient whose position cannot be adjusted freely and the posture of the doctor who performs the procedure by the side of the table. Get closer and make it easier.
IntelliSHUTTER / Independent Collimator Shutter [OPTION]
You can eliminate exposures to the specific unnecessary field outside of the Region of Interest. Upper. Lower. Left. Right. The four shutters slide independently, making exams at the edge of the table easier. The upper half for urological cystography. The left half for shoulder arthrography. No need to move the patient. Shape the beam as per your wish.
Minimum dose. Maximum vision.
Safety for all translates primarily into the dose reduction. Our answer was to change the standard of dose care with a whole new program. With numerous technologies born in the medical sites, your low dose has evolved as IntelliDOSE.
IntelliFRAME / Frame Conversion [OPTION]
Reduce the dose to half without sacrificing smoothness. Typically, the more pulse you shoot, the smoother the fluoroscopy becomes. IntelliFRAME will blow your mind. Set the pulse rate to 1/2 and activate IntelliFRAME. The dose becomes 50%, yet smoothness maintains by frame interpolation. EndoTherapy. Pediatrics. OB/GYN. Half dose with no image degradation.
IntelliCUT / Active Dose Reduction
No one wants to receive radiation dose that
does not contribute to imaging. ‟Trail effect” is an active dose that does not contribute to imaging. IntelliCUT significantly reduces unwanted X-ray exposure by Trail Cut-off on every pulse. Patients. Doctors. Nurses. Radiographers. etc… Eliminate unwanted scattered radiation for everyone with IntelliCUT.
IntelliSHOT / Fluoro. Screenshot
Dose-free screenshot. All-you-can-take! You can save high-quality fluoroscopy as static images at your desired timing (sent in DICOM format). It captures a specific frame of the fluoroscopy, hence there is no more dose due to additional exposures. With CUREVISTA Open, let’s take screenshots, instead of additional exposures.